X-AM 8000

Dräger X-AM 8000

Clearance measurement was never easier with the Dräger X-AM 8000. It can measures up to seven gases, including toxic, flammable gases and vapours, and oxygen all at once. Available in either in pump or diffusion mode, its innovative signalling design ensures complete safety throughout the process.

Category: ,

Tags:

  • Specially designed for use with a pump, optimized for clearance measurement
  • Connected with hoses up to 147 ft (45 meters) long
  • Clearance measurement, release and documentation in no time
  • Intuitive to operate with one-handed operation using three function keys
  • Clear signalling design: 
    • Red light = gas alarm
      Yellow light = device-related alarm, e.g. low battery
      Green light = device is ready for use
      A loud horn (100 dB(A)
  • Equipped with a shock detection system
  • Measure Hard-to-Detect hydrocarbons with one of two high-performance PID sensors
  • Charging cradles can connect with one another, taking up minimal space
  • Size: 179 x 77 x 42 mm (7.0″ x 3.0″ x 1.7″)
  • Weight: 495 – 550 g (17.5 – 19.4 oz) Depending on sensor configuration and inclusion of pump
  • Ambient Conditions:
    • Temperature: – 20 to + 50 °C (-4 to 122°F)
    • Pressure: 700 to 1300 mbar (20.7 to 38.4 inch Hg)
    • Relative Humidity: 10 to 95 % r.h.
  • Protection Class: IP 67
  • Alarms:
    • Visual: 3 LED ‘red’ ; 3 LED ‘yellow’
    • Vibrating
    • Audible: Multi-tone, typically 100 dB(A) at 30 cm
  • Operating Times:
    • Typically 24h with CatEx and 3 EC sensors
    • Typically 22h with IR and 3 EC sensors
    • Typically 120h with 3 EC-sensors
    • Typically 17h with CatEx, PID and 3 EC sensors
    • Typically 16h with IR, PID and 3 EC sensors
    • Typically 42h with PID only
  • Charging Time:  Typically 4 Hours
  • Data Storage:12 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 4 channels: Approx. 300 hours
Sensor Type Measuring Range Resolution
Cat-Ex 125 PR 0 – 100% LEL; 0 – 100 Vol% 1% LEL
Cat-Ex 125 PR Gas 0 – 100% LEL; 0 – 100 Vol% 1% LEL
Dual IR Ex/CO2 0 – 100% LEL; 0 – 100 Vol%; 0-5 Vol% CO2 1% LEL; 0.2 Vol%; 50 ppm CO2
IR Ex 0 – 100% LEL; 0 – 100 Vol% 1% LEL; 0.2 Vol%
IR CO2 0 – 5 Vol% 0.01 Vol% or 50 ppm
DrägerSensor PID LC ppb (10.6 eV) 0.025 – 10 ppm Isobutylene 0-2ppm/10ppb; >2-5ppm/20ppb; >5-10ppm/50ppb
DrägerSensor PID HC (10.6 eV) 0 – 2000 ppm Isobutylene **See Datasheet
XXS O2 0 – 25 Vol% 0.1 Vol%
XXS O2 100 0 – 100 Vol% 0.5 Vol%
XXS CO LC 0 – 2000 ppm 1 ppm
XXS CO HC 0 – 10000 ppm 5 ppm
XXS CO/H2 comp. 0 – 2000 ppm 2 ppm
XXS H2S LC 0 – 100 ppm 0.1 ppm
XXS H2S HC 0 – 1000 ppm 2 ppm
XXS CO LC / H2S LC 0 – 2000 ppm; 0 – 100 ppm H2S 1 ppm CO; 0.1 ppm H2S
XXS CO LC / O2 0 – 2000 ppm; 0 – 25 Vol% O2 1 ppm CO; 1% O2
XXS NO 0 – 200 ppm 0.1 ppm
XXS NO2 0 – 50 ppm 0.1 ppm
XXS NO2 LC 0 – 50 ppm 0.02 ppm
XXS SO2 0 – 100 ppm 0.1 ppm
XXS PH3 0 – 20 ppm 0.01 ppm
XXS PH3 HC 0 – 2000 ppm 1 ppm
XXS HCN 0 – 50 ppm 0.1 ppm