X-ACT® 7000
Dräger X-ACT® 7000
The Dräger X-ACT® 7000 gas analysis system lets you measure gases in the low ppb range, replacing slow, expensive lab analyses with quick, onsite measurements. Consisting of Dräger MicroTubes and an opto-electronic analysis device, it’s extremely easy to use. Simply insert the Dräger MicroTubes, start measuring and then read out the test result.
After an automatic self-test, the X-act 7000 analysis system is immediately ready for use. The automatic drive carefully draws the MicroTube in and positions it. Control your test using the 3-button control and 2.4″ colour display. When the test is complete, the green LED will glow and a message is displayed on the screen. You can store the test result, location and time in the internal data logger and read it later using the Dräger CC Vision software.
Category: Dräger Safety, Gas Detection Tubes
Tags:
- 160° viewing angle
- Day/night reading mode
- 3-button control
- LED status indicator
- Sample up to a distance of 45 meters (147.6 feet) using the X-AM Pump
- Measures the lowest-quantity concentrations with lab-quality analysis
- More safety thanks to high selectivity (substance-specific reactive layers and multiple pre-layers in the Dräger MicroTubes)
- Explosion-proof and ready to use
- Dust- and splash-resistant
- Certified under ATEX and CSA
- Size: 195 mm x 85 mm x 70 mm (7.7 in x 3.3 in x 2.8 inches)
- Measuring Range and Resolution: Varies, depending on the Dräger MicroTubes in use
- Typical Testing Time: From 5 seconds to 1,200 seconds, depending on the Dräger MicroTubes in use and the concentration of the test substance
- Operating Temperature: 0 to +50 °C (+32 to +122 °F)
- Storage Temperature: -20 to +55 °C (-4 to +131 °F) (Analyzer); +4 to +25 °C (+39 to +77 °F) (Dräger MicroTubes)
- Air Pressure: 700 to 1,300 hPa
- Humidity: 0 to 95 % relative humidity, non-condensing
- Recording of Measured Data: CMOS sensor optics and LED light
- Display: 2.4" high contrast, colour display with a resolution of 240 x 320, viewing angle of 160°
- Opeating Time: Approx. 600 minutes of testing time
- Protection Class: IP54
Sensor Type | Measuring Range | Test Time |
---|---|---|
Ammonia | 1 - 100 ppm | 10 - 75 seconds |
Ammonia | 100 - 2,500 ppm | 3 - 45 seconds |
Benzene | 1 - 150 ppb | 100 - 900 seconds |
Benzene | 0.15 - 10 ppm | 25 - 150 seconds |
1,3-Butadiene | 25 - 500 ppb | 200 - 600 seconds |
1,3-Butadiene | 0.5 - 25 ppm | 10 - 280 seconds |
Carbon Dioxide | 200 - 50,000 ppm | 2 - 120 seconds |
Carbon Monoxide | 10 - 1,000 ppm | 5 - 300 seconds |
Chlorine | 50 - 5,000 ppb | 10 - 400 seconds |
Ethylene Oxide | 25 - 250 ppb | 150 - 600 seconds |
Ethylene Oxide | 0.25 - 10 ppm | 100 - 500 seconds |
Formaldehyde | 5 - 150 ppb | 360 - 960 seconds |
Formaldehyde | 0.15 - 3 ppm | 300 - 600 seconds |
Hydrochloric Acid | 0.5 - 25 ppm | 10 - 100 seconds |
Hydrocyanic Acid | 0.5 - 50 ppm | 20 - 180 seconds |
Hydrogen Sulphide | 0.1 - 50 ppm | 5 - 960 seconds |
Mercury | 0.005 - 0.25 mg/m³ | 240 - 1,200 seconds |
Nitrogen Dioxide | 0.25 - 50 ppm | 10 - 210 seconds |
Nitrous Fumes | 0.25 - 50 ppm | 5 - 120 seconds |
Petroleum Hydrocarbons | 10 - 3,000 ppm | 10 - 360 seconds |
Sulphur Dioxide | 0.05 - 5 ppm | 20 - 480 seconds |
Toluene | 10 - 1,000 ppm | 6 - 360 seconds |
Xylene | 10 - 1,000 ppm | 10 - 240 seconds |