ToxiRAE Pro

ToxiRAE Pro

The ToxiRAE Pro is the world’s first wireless personal monitor for toxic gases and oxygen. The ToxiRAE provides safety professionals wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response. The ToxiRAE Pro’s intelligent interchangeable sensors store calibration data, which allows users to monitor for one gas one day and another gas the next, by simply swapping the sensors in the ToxiRAE Pro.

Available Gases:

  • NH3
  • CO
  • CO: Ext. Range
  • CO: H2 Comp
  • Cl2
  • ClO2
  • ETO-A
  • ETO-B
  • ETO-C: Ext. Range
  • HCHO (Formaldehyde)
  • H2
  • HCN
  • H2S
  • H2S: Ext. Range
  • CH3-SH (Methyl Mercaptan)
  • NO
  • NO2
  • O2
  • PH3
  • SO2
  • Personal wireless monitor for toxic gases and oxygen
  • Swap out sensors for different gases
  • Sensors store calibration data even when swapped out
  • 5-way local and remote wireless alarm system
  • Largest display in class
  • Water-, dust-, and shock-resistant
  • Compatible with AutoRAE 2 (Fully automatic bump testing and calibration)
  • Built-in man-down alarm
  • Most sensors can be shared with MultiRAE instrument family
  • Size: 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
  • Weight: 7.76 oz. (220 g)
  • Battery: Rechargeable Li-ion battery
  • Operating time: > 30 hours (normal operation, non-wireless)
  • Recharge time: < 4 hours through charging cradle
  • Operating Temperature: -4° to 131°F (-20° to 55°C)
  • Humidity: 0% to 95% relative humidity (non-condensing)
  • Dust and Water Resistance: IP-65 rating
  • Display: Graphical LCD display with white LED backlighting
  • Display Readout:
    • Real-time reading of gas concentrations
    • Battery status
    • Data logging on/off
    • Wireless on/off
    • Reception quality
    • STEL, TWA, and peak values
  • Keypad: 2 buttons for operation and programming
  • Alarms:
    • Wireless remote alarm notification
    • Audible (95 dB @ 30 cm)
    • Vibration
    • Visible alarm (flashing bright red LEDs)
    • On-screen indication of alarm conditions.
    • Man Down Alarm with pre-alarm and real-time remote wireless notification
  • Datalogging: Continuous datalogging with a three-month capacity
  • Wireless Network:
    • ProRAE Guardian Real-Time Wireless Safety System
    • Loop Network with the EchoView Host
  • Wireless Range (Typical)
    • ToxiRAE Pro to Mesh Router, EchoView Host, or Mesh Reader 2: ~ 660 feet (200 meters)
    • ToxiRAE Pro to RAELink3 Mesh or RAELink3 Z1 Mesh modems: ~ 330 feet (100 meters)
Sensor Type Measuring Range Resolution
NH3 0 – 100 ppm 1 ppm
CO 0 – 500 ppm 1 ppm
CO (Ext. Range) 0 – 2000 ppm 10 ppm
CO (H2 – Comp) 0 – 2000 ppm 10 ppm
Cl2 0 – 50 ppm 0.1 ppm
ClO2 0 – 1 ppm 0.03 ppm
ETO-A 0 – 100 ppm 1 ppm
ETO-B 0 – 10 ppm 0.1 ppm
ETO-C (Ext. Range) 0 – 500 ppm 10 ppm
HCHO (Formaldehyde) 0 – 500 ppm 1 ppm
HCN 0 – 50 ppm 0.5 ppm
H2S 0 – 100 ppm 0.1 ppm
H2S (Ext. Range)
0 – 1000 ppm 1 ppm
CH3-SH (Methyl Mercaptan) 0 – 10 ppm 0.1 ppm
NO 0 – 250 ppm 0.5 ppm
NO2 0 – 20 ppm 0.1 ppm
O2 0 – 30% 0.1%
PH3 0 – 20 ppm 0.1 ppm
SO2 0 – 20 ppm 0.1 ppm