Pac 8500

Pac 8500

​The Dräger Pac 8500 single-gas detection device is a reliable and precise instrument even under the toughest of conditions. The detector can be equipped with a hydrogen-compensated CO sensor or a Dräger dual sensor. The dual sensors provide the option of measuring two gases at once: either H2S with CO or O2 with CO.

Available Gases

  • NO • CO2 • CL2 • HCN • NH3 • PH3 • OV • OV-A • NO2 • O3 (Ozone) • COCl2

Category: ,

Tags:

  • Reliable, precise readings at any time even in extreme conditions
  • Very low T-90 response time
  • Two gas detection in a single-gas device
  • Shock-proof, chemical-resistant housing meets the requirements specified by the IP68 standard rating.
  • Measurement of carbon monoxide with significantly reduced cross sensitivity
  • D-Light indicates the functionality of the device and if it’s ready to use.
  • Large display clearly indicates the respective gas concentration
  • 360° alarm with various functions
  • Two bright, flashing LEDs
  • Acoustic alarm reaches a volume of 90 dB
  • Logs concentrations and events along with date and time
  • Size: (without clip): (W x H x D) 2.5 x 3.3 x 0.8 in (64 x 84 x 20 mm)
  • Weight: Approx. 3.7 ounces, 106 g (4.0 ounces, 113 g with clip)
  • Battery service life: Min. 2 years (O2 and dual sensors min. 12 months)
  • Protection class: IP68
  • Air pressure: 700 to 1,300 hPa
  • Air humidity: 10 to 90% relative humidity, non-condensing
  • Operating Temperature: -22 °F to 131 °F, -30 °C to +55 °C (briefly down to -40 °F / -40 °C for 1 hr, depending on sensor)
Sensor Type Measuring Range Alarm Setpoints
H2S/CO 0 – 50 ppm H2S; 0 – 2000 ppm CO 10 / 15 ppm H2S; 35 / 50 ppm CO
O2/CO 0 – 25 %vol. O2; 0 – 2000 ppm CO 19.5 / 23.5 %vol. O2; 35 / 50 ppm CO
CO-H2 CP 0 – 2000 ppm 35 / 50 ppm
CO-H2 CP (Canada) 0 – 2000 ppm 25 / 50 ppm