BW Clip4
BW Clip4
When you’ve got your hands full in the field, you need no‑hassle gas detection you can count on: the BW Clip4 four-gas detector. Wearable, easy multi-gas detection that’s always on. No charging, no battery replacement, no hassle. Simpler, low cost of ownership guaranteed by the Honeywell commitment to quality, and backed by a full ecosystem of supporting technologies. When you clip on the BW Clip4 you know – it’s on.
Always On: 2-Year Continuous Runtime.
Once activated, you can rest assured that the BW Clip4 is always on. The BW Clip4 is easy to wear and use. Lower your maintenance costs with two years of continuous runtime without charging and no battery or sensor replacements. Simply turn your new detector on and then after two years replace it for a new one.
Category: BW Technologies by Honeywell, Multi-Gas
Tags: Disposable
- Durable, ergonomic and wearable — doesn’t weigh you down
- Compact profile — even working in tight spaces, you won't know you are wearing it
- Simple one-button operation
- User-friendly tamper-proof operation with just one button
- Intuitive LCD icons
- Real-time gas concentrations shown on LCD
- Flashing red non-compliance indicators warn workers that the detector has not been bump tested according to schedule
- Daily full function self-test of sensors, battery status, circuit integrity, and audible/visual alarms
- Compatible with IntelliDoX docking system and instrument management system
- Built-in concussion proof boot
- Tested to last in extreme environment
- Size: 4.7 x 2.7 x 1.3 inches / 12.0 x 6.8 x 3.2 cm
- Weight: 8.2 oz. / 233 g
- Operating Temperature: -4 to +131°F / -20 to +50°C
- Humidity: 5 - 95% RH (non-condensing) continuous
- Ingress Protection: IP68
- Alarms and Type:
- Visual
- Vibrating
- Audible (95 dB)
- Low, High, TWA, STEL, OL (over limit)
- Self-Test: Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery, and circuitry).
- Typical Battery Life: Two years, Continuous Operation
- Event Logging: 70 most recent events
- User Options:
- Adjust STEL period (5-15 minutes in 1 minute intervals)
- Calibration span levels
- Calibration interval
- Bump test interval
- Select combustible gases measurement: 0-100% LEL (Lower Explosive Limit) or Methane gas 0-5.0% v/v
- Calibration due date (1 to 365 days, or set to zero for off)
- Individual sensor enable/disable
- Latching alarms
- Stealth mode
- Warranty: Full two-year warranty including sensors and battery
Sensor Type | Measuring Range | Resolution |
---|---|---|
H2S | 0 - 100 ppm | 1 / 0.1 ppm |
CO | 0 - 1000 ppm | 1 ppm |
LEL | 0 - 100% LEL | 1% |
O2 | 0 - 25% | 0.1% |