RKI Eagle

RKI Eagle

The Eagle is the most versatile portable gas detector on the market. The Eagle is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S, and CO. Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life, and field proven sensors.

Some of the unique Eagle features that make this monitor so special include: PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges; a methane elimination switch for environmental applications, a long list of super toxic gases and measurable ranges, and dual hydrophobic filters. Its strong internal pump with a low flow auto shut off an alarm, which can draw samples from up to 125 feet even with the dual hydrophobic filters in place. This allows for quick response and recovery from distant sampling locations.

Category: , ,

Tags: ,

  • Simultaneous detection of up to 6 different gases
  • Over 400 gas monitoring configurations
  • A wide range of toxic gases
  • PPM / LEL hydrocarbon detection
  • Powerful long-life pump up to 125’ range with filters
  • Up to 30 hours of continuous operation
  • Dual hydrophobic filters (most versions)
  • IR Sensors available for CO2, % LEL CH4 or HC, % volume CH4 or HC
  • Transformer testing version available
  • Intrinsically safe design, CSA (C / US) & UL classified (most versions)
  • Complies with EPA Method 21
  • Dimensions: 10.5″ long x 5.9″ x 7″ tall
  • Weight: 5 lbs.
  • Alarm Types: 2 alarms per channel plus TWA and STEL alarms. Fully adjustable for levels, latching or self-reset and silenceable
  • Alarm Methods: Buzzer 85dB at 30 cm, dual high-intensity LED’s, and blinking display
  • Sample Method: Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH
  • Response Time: 30 seconds to 90% (for most gases)
  • Display: 4 x 20 LCD readout with backlighting. Viewed through window in case top. Displays readings & status of all channels simultaneously
  • Continuous Operation: 30 hours minimum using alkaline batteries, or 18 hours using Ni-Cads
  • Operating Temperature: –10°C to 40°C (14°F to 104°F)
  • Relative Humidity: 0- 95% RH non condensing
  • Warranty: One-year material and workmanship

<td± 10% of reading or ± 5% of full scale

Sensor Type Measuring Range Accuracy of Statement
Hydrobards (Methane Std.) 0 – 100% LEL ± 5% of reading or ± 2% LEL (LEL mode only)
O2 0 – 40% Vol. ± 0.5% O2
CO 0 – 500 ppm ± 5% of reading or ± 5 ppm CO
H2S 0 – 100 ppm ± 5% of reading or ± 2 ppm H2S
NH3 0 – 75 ppm ± 10% of reading or ± 5% of full scale
AsH3 0 – 1 ppm; 0 – 200 ppb ± 10% of reading or ± 5% of full scale
Cl2 0 – 3 ppm ± 10% of reading or ± 5% of full scale
ClO2 0 – 1 ppm ± 10% of reading or ± 5% of full scale
F2S 0 – 5 ppm ± 10% of reading or ± 5% of full scale
HF 0 – 9 ppm ± 10% of reading or ± 5% of full scale
HCl 0 – 15 ppm ± 10% of reading or ± 5% of full scale
HCN 0 – 30 ppm ± 10% of reading or ± 5% of full scale
H2Se 0 – 0.2 ppm ± 10% of reading or ± 5% of full scale
H2S 0 – 1 ppm; 0 – 30 ppm ± 10% of reading or ± 5% of full scale
NO2 0 – 15 ppm ± 10% of reading or ± 5% of full scale
O3 0 – 1 ppm ± 10% of reading or ± 5% of full scale
NO 0 – 100 ppm ± 10% of reading or ± 5% of full scale
PH3 0 – 1 ppm ± 10% of reading or ± 5% of full scale
SiH4S 0 – 15 ppm ± 10% of reading or ± 5% of full scale
SO2 0 – 6 ppm ± 10% of reading or ± 5% of full scale
CO2 (IR) 0 – 5000 ppm ± 5% of reading or ± 2% of full scale
CO2 (IR) 0 – 10000 ppm ± 5% of reading or ± 2% of full scale
CO2 (IR) 0 – 5% Vol. ± 5% of reading or ± 2% of full scale
CO2 (IR) 0 – 20% Vol. ± 5% of reading or ± 2% of full scale
CO2 (IR) 0 – 60% Vol. ± 5% of reading or ± 2% of full scale
Methane CH4 (IR) 0 – 100% LEL ± 5% of reading or ± 2% of full scale
Methane CH4 (IR) 0 – 100% Vol. ± 5% of reading or ± 2% of full scale
Isobutane 0 – 100% LEL ± 5% of reading or ± 2% of full scale
Isobutane 0 – 100% Vol. ± 5% of reading or ± 2% of full scale